Every ConnectWise ScreenConnect CVE that CISA lists as exploited, with the fixed versions, scores and dates from ConnectWise, CISA and NVD. Use it to check your server and clients.
See the CVE tableCISA’s Known Exploited Vulnerabilities catalog lists four ScreenConnect CVEs: CVE-2026-84869, CVE-2025-3935, CVE-2024-1708 and CVE-2024-1709. What to do: upgrade on-premises servers to the latest supported release, then reinstall host clients and update access agents. Cloud or on-premises, check that every technician’s ScreenConnect client runs 26.6.5 or later, as ConnectWise’s November 16, 2026 advisory requires. ConnectWise has already updated its cloud servers. Patching does not remove an attacker who is already in.
Newest disclosed first. Checked against the CISA KEV catalog of November 18, 2026, the NVD records and the ConnectWise bulletins.
| CVE | What it is | Affected / fixed | CVSS | Added to CISA KEV | Known ransomware use |
|---|---|---|---|---|---|
CVE-2026-84869 |
Client flaw: files can be transferred and run through an active session without authorization or Host confirmation, in certain circumstances. Servers are not impacted. | Clients before 26.6.5 / fixed in 26.6.5 (NVD build cutoff: 26.6.5.9742) | 9.9 (ConnectWise, CVSS 3.1) | September 11, 2026 | Unknown |
CVE-2025-3935 |
ViewState code injection on the server. Only possible if the attacker already has the server’s machine keys. | 25.2.3 and earlier / fixed in 25.2.4 (patches also for some older versions back to 23.9) | 7.2 (NVD), 8.1 (ConnectWise), CVSS 3.1 | June 2, 2025 | Unknown |
CVE-2024-1708 |
Path traversal on the server, which may allow remote code execution. | 23.9.7 and prior / fixed in 23.9.8 (see the 22.4 note below) | 8.4 (NVD, CVSS 3.1) | April 28, 2026 | Known |
CVE-2024-1709 |
Authentication bypass: an attacker with network access to the management interface can create a new administrator-level account. | 23.9.7 and prior / fixed in 23.9.8 and in interim build 22.4.20001.8817 | 10.0 (NVD, CVSS 3.1) | February 22, 2024 | Known |
The server check applies to on-premises servers. ConnectWise updates its own cloud servers. Technician clients need checking on both.
If your license is out of maintenance, check Latest Eligible Version on Administration > Overview first: ConnectWise says partners whose renewal is due in 2026 can upgrade to 26.6 without renewing. Otherwise, ConnectWise says to upgrade your license before installing the latest release. ConnectWise says on-premises servers must already run 25.4 or later to upgrade to 26.6.5, so older servers need to upgrade in steps. Follow the upgrade path in the bulletin for your version. If your path includes the 25.2.4 upgrade, its bulletin says to update access agents after each incremental upgrade. For on-premises ScreenConnect integrated with Automate, ConnectWise supplies 26.6.5 through Automate Product Updates for partners with active Automate Assurance.
A condition in the ScreenConnect client may allow files to be transferred and executed through an active remote session without authorization or Host confirmation, in certain circumstances. ConnectWise says ScreenConnect servers are not impacted. ConnectWise rates it 9.9 (CVSS 3.1). CISA added it to its exploited list on September 11, 2026.
How to check if you’re affected: check the ScreenConnect client version on every technician workstation. Each must run 26.6.5 or later, cloud or on-premises. A server upgrade alone is not the whole fix. After patching, ConnectWise says to review users, roles and permissions, remove users you don’t recognize, change passwords and enable MFA.
It is being exploited: Huntress reported on November 16, 2026 that it confirmed in-the-wild exploitation of CVE-2026-84869. It observed one technician’s client run a guest-pushed batch file and another technician’s client open a guest-pushed text file. Huntress suggests looking for the ScreenConnect client on technician workstations running scripts from its Documents\...\Temp folder, and for Startup entries you didn’t add, such as Sync.bat. For the November activity, ConnectWise advises partners to preserve and review Run Command history, extension API activity, admin accounts, permission changes and Toolbox records. From a trusted device, revoke active ScreenConnect web sessions and associated identity-provider sessions, reset relevant credentials and enforce MFA. A password reset alone does not end all existing sessions. If you suspect compromise, isolate affected devices and preserve evidence. Use endpoint detection and response tools or another trusted out-of-band method to investigate and remediate affected devices. Include any technician workstations that connected to those devices. If a technician workstation was compromised, rotate all credentials accessible from it, including RMM, PSA, ScreenConnect, password vault and customer administrator credentials. Do not use ScreenConnect to investigate or clean suspected compromised endpoints. Clear unauthorized queued commands and tools, remove persistence and validate remediation before restoring connectivity.
U.S. federal agencies: CISA’s KEV entry set a September 14, 2026 due date. Covered agencies must apply the vendor’s mitigations, comply with BOD 26-04 and follow CISA’s forensic triage requirements. Follow the applicable cloud guidance or discontinue use if mitigations are unavailable.
ScreenConnect 25.2.3 and earlier may be open to a ViewState code injection attack. An attacker needs the server’s ASP.NET machine keys. ConnectWise says extracting them from the server takes privileged system-level access. Treat keys that have already been exposed as compromised. With the keys, an attacker could send a malicious ViewState to the server and possibly run code on it. NVD scores it 7.2 and ConnectWise 8.1 (CVSS 3.1). ConnectWise says it had no direct impact on the ScreenConnect client. CISA added it on June 2, 2025.
How to check if you’re affected: on the Version Check box, a server on 25.2.3 or earlier is affected unless it runs one of the patched older builds published April 22, 2025 or later.
ScreenConnect 23.9.7 and prior have a path traversal flaw that may let an attacker execute remote code or directly impact confidential data or critical systems. NVD scores it 8.4 (CVSS 3.1). It was fixed in the same February 2024 release as CVE-2024-1709, but CISA only added it to its exploited list on April 28, 2026, and marks known ransomware use. A Microsoft Security Blog post of April 6, 2026 lists CVE-2024-1708 and CVE-2024-1709 among the flaws exploited by Storm-1175, a group that deploys Medusa ransomware.
How to check if you’re affected: a server on 23.9.7 or earlier is affected (see the 22.4 note above). ConnectWise also says to review installed extensions, and that .aspx or .ashx files in the server’s App_Extensions folder may be a sign this flaw was exploited.
ScreenConnect 23.9.7 and prior have an authentication bypass. CISA says an attacker with network access to the management interface can create a new administrator-level account. NVD scores it 10.0 (CVSS 3.1), the maximum. CISA added it to its exploited list on February 22, 2024, and marks known ransomware use.
How to check if you’re affected: a server on 23.9.7 or earlier is affected unless it runs the interim 22.4.20001.8817 build or a later eligible patched build that ConnectWise says includes the CVE-2024-1709 fix. After patching for the two 2024 CVEs, ConnectWise says to review the configuration and user accounts, remove unrecognized users, change passwords and enable MFA. Validate installed extensions, remove and reinstall only those approved for use, and restart the server after completing these steps. Keep the extensions identified in the November 2026 advisory disabled.
Not by itself. It is legitimate remote-support software. Here is how to find out who controls it.
ScreenConnect is legitimate remote-support software made by ConnectWise. Many IT providers install it so they can fix computers remotely. Scammers use it too, often after a call or email claiming your computer has a problem. ConnectWise’s advice is to never let someone access your machine unless you contacted them first.
ScreenConnect Client (xxxxxxxxxxxxxxxx). ConnectWise says the code in brackets is a thumbprint unique to each ScreenConnect installation, so entries with different codes belong to different installations.Not finding an entry doesn’t prove there is nothing there. Huntress has reported a script that installs a hidden ScreenConnect client and then removes its Windows uninstall entry. If you think your computer was taken over, ask an IT provider to check it.
Patching, client updates and disabling the RMM+ extensions come first. A blocklist only reduces how often attackers can try.
The standard ThreatListPro feed covers 5.4M+ IPv4 addresses from real attacks on live production Palo Alto GlobalProtect VPN portals in the US and is checked for new attackers every 6 hours. It loads on the firewall as a plain-text feed. You can test the free sample first, with no signup. To check one address, use the IP check tool.
Run ScreenConnect on-premises? The Secure ScreenConnect playbook is the step-by-step method we used to secure our own server. It is a $79 PDF for on-premises servers and adds to the vendor steps; it doesn’t replace them.
Four. As of November 18, 2026, CISA's Known Exploited Vulnerabilities catalog lists CVE-2026-84869, CVE-2025-3935, CVE-2024-1708 and CVE-2024-1709 for ConnectWise ScreenConnect. CISA marks known ransomware use for CVE-2024-1709 and CVE-2024-1708.
The newest one in CISA's exploited list is CVE-2026-84869, a client flaw fixed in ScreenConnect 26.6.5 and added to the list on September 11, 2026. CVE-2026-127063, published November 12, 2026, is newer, but it is in the third-party RMM+ extension, not in the ScreenConnect server or client, and it is not in CISA's list.
ConnectWise says it has already updated its cloud-hosted ScreenConnect servers for all four exploited CVEs. Cloud partners still have work to do for CVE-2026-84869: reinstall host clients, update access agents and check that every technician workstation runs client 26.6.5 or later. ConnectWise's November 16, 2026 advisory requires that check for cloud and on-premises partners. On-premises servers must be upgraded by their owners.
Sign in to your on-premises server as an administrator. ConnectWise's 26.6.5 bulletin points to Administration > Overview for your current and eligible version; its CVE-2025-3935 bulletin points to Administration > License > Version Check. A server older than 26.6.5 does not have the update for CVE-2026-84869. That flaw is in the client, so after upgrading, reinstall host clients, update access agents and check the client version on every technician workstation.
Not by itself. ScreenConnect is legitimate remote-support software that many IT providers use. Scammers use it too. If you don't know who installed it, ask your IT provider. On a work computer, contact your IT or security team and follow their instructions so they can preserve evidence. On a personal computer, uninstall the ScreenConnect Client entry if you confirm nobody you trust installed it.
No. Install the relevant ScreenConnect server and client updates. Keep the identified RMM+ extensions disabled pending ConnectWise guidance. A blocklist on the firewall in front of your server can reduce scanning and login attempts from known attacker addresses.
The standard ThreatListPro feed covers 5.4M+ IPv4 addresses and is checked for new attackers every 6 hours, as a plain-text feed for your firewall. Monthly is $19.99 with a 14-day free trial and no card needed.
Start a 14-day free trialPrimary sources reviewed November 18, 2026.
ScreenConnect and remote-access reading.